man.bsd.lv manual page server

Manual Page Search Parameters

ZIC(8) System Manager's Manual ZIC(8)

zictimezone compiler

zic [--version] [-Dsv] [-d directory] [-g group] [-L leapsecondfilename] [-l localtime] [-m mode] [-p posixrules] [-u user] [-y command] [filename ...]

The zic utility reads text from the file(s) named on the command line and creates the time conversion information files specified in this input. If a filename is -, the standard input is read.

The following options are available:

Output version information and exit.
Do not automatically create directories. If the input file(s) specify an output file in a directory which does not already exist, the default behavior is to attempt to create the directory. If -D is specified, zic will instead error out immediately.
directory
Create time conversion information files in the named directory rather than in the standard directory named below.
group
After creating each output file, change its group ownership to the specified group (which can be either a name or a numeric group ID).
leapsecondfilename
Read leap second information from the file with the given name. If this option is not used, no leap second information appears in output files.
timezone
Use the given time zone as local time. The zic utility will act as if the input contained a link line of the form

Link timezone localtime

(Note that this action has no effect on FreeBSD, since the local time zone is specified in /etc/localtime and not /usr/share/zoneinfo/localtime.)

mode
After creating each output file, change its access mode to mode. Both numeric and alphabetic modes are accepted (see chmod(1)).
timezone
Use the given time zone's rules when handling POSIX-format time zone environment variables. The zic utility will act as if the input contained a link line of the form

Link timezone posixrules
user
After creating each output file, change its owner to user (which can be either a name or a numeric user ID).
Complain if a year that appears in a data file is outside the range of years representable by time(3) values.
Limit time values stored in output files to values that are the same whether they are taken to be signed or unsigned. You can use this option to generate SVVS-compatible files.
command
Use the given command rather than when checking year types (see below).

Input lines are made up of fields. Fields are separated from one another by any number of white space characters. Leading and trailing white space on input lines is ignored. An unquoted sharp character (#) in the input introduces a comment which extends to the end of the line the sharp character appears on. White space characters and sharp characters may be enclosed in double quotes (") if they are to be used as part of a field. Any line that is blank (after comment stripping) is ignored. Non-blank lines are expected to be of one of three types: rule lines, zone lines, and link lines.

Names (such as month names) must be in English and are case insensitive. Abbreviations, if used, must be unambiguous in context.

A rule line has the form:

Rule NAME FROM TO TYPE IN ON AT SAVE LETTER/S
For example:
Rule US 1967 1973 - Apr lastSun 2:00 1:00 D

The fields that make up a rule line are:

NAME
Give the (arbitrary) name of the set of rules this rule is part of.
FROM
Give the first year in which the rule applies. Any integer year can be supplied; the Gregorian calendar is assumed. The word minimum (or an abbreviation) means the minimum year representable as an integer. The word maximum (or an abbreviation) means the maximum year representable as an integer. Rules can describe times that are not representable as time values, with the unrepresentable times ignored; this allows rules to be portable among hosts with differing time value types.
TO
Give the final year in which the rule applies. In addition to minimum and maximum (as above), the word (or an abbreviation) may be used to repeat the value of the FROM field.
TYPE
Give the type of year in which the rule applies. If TYPE is - then the rule applies in all years between FROM and inclusive. If TYPE is something else, then zic executes the command yearistype year type to check the type of a year: an exit status of zero is taken to mean that the year is of the given type; an exit status of one is taken to mean that the year is not of the given type.
IN
Name the month in which the rule takes effect. Month names may be abbreviated.
ON
Give the day on which the rule takes effect. Recognized forms include:

5
the fifth of the month
lastSun
the last Sunday in the month
lastMon
the last Monday in the month
Sun>=8
first Sunday on or after the eighth
Sun<=25
last Sunday on or before the 25th

Names of days of the week may be abbreviated or spelled out in full. Note that there must be no spaces within the field.

AT
Give the time of day at which the rule takes effect. Recognized forms include:

2
time in hours
2:00
time in hours and minutes
15:00
24-hour format time (for times after noon)
1:28:14
time in hours, minutes, and seconds

where hour 0 is midnight at the start of the day, and hour 24 is midnight at the end of the day. Any of these forms may be followed by the letter ‘w’ if the given time is local “wall clock” time, ‘s’ if the given time is local “standard” time, or ‘u’ (or ‘g’ or ‘z’) if the given time is universal time; in the absence of an indicator, wall clock time is assumed.

SAVE
Give the amount of time to be added to local standard time when the rule is in effect. This field has the same format as the AT field (although, of course, the ‘w’ and ‘s’ suffixes are not used).
LETTER/S
Give the “variable part” (for example, the “S” or “D” in “EST” or “EDT”) of time zone abbreviations to be used when this rule is in effect. If this field is -, the variable part is null.

A zone line has the form:

Zone NAME GMTOFF RULES/SAVE FORMAT [UNTILYEAR [MONTH [DAY [TIME]]]]
For example:
Zone Australia/Adelaide 9:30 Aus CST 1971 Oct 31 2:00
The fields that make up a zone line are:
NAME
The name of the time zone. This is the name used in creating the time conversion information file for the zone.
GMTOFF
The amount of time to add to UTC to get standard time in this zone. This field has the same format as the AT and fields of rule lines; begin the field with a minus sign if time must be subtracted from UTC.
RULES/SAVE
The name of the rule(s) that apply in the time zone or, alternately, an amount of time to add to local standard time. If this field is - then standard time always applies in the time zone.
FORMAT
The format for time zone abbreviations in this time zone. The pair of characters is used to show where the “variable part” of the time zone abbreviation goes. Alternately, a slash (/) separates standard and daylight abbreviations.
UNTILYEAR [MONTH [DAY [TIME]]]
The time at which the UTC offset or the rule(s) change for a location. It is specified as a year, a month, a day, and a time of day. If this is specified, the time zone information is generated from the given UTC offset and rule change until the time specified. The month, day, and time of day have the same format as the IN, ON, and AT fields of a rule; trailing fields can be omitted, and default to the earliest possible value for the missing fields.

The next line must be a “continuation” line; this has the same form as a zone line except that the string “Zone” and the name are omitted, as the continuation line will place information starting at the time specified as the until information in the previous line in the file used by the previous line. Continuation lines may contain until information, just as zone lines do, indicating that the next line is a further continuation.

A link line has the form

Link LINK-FROM LINK-TO
For example:
Link Europe/Istanbul Asia/Istanbul
The field should appear as the NAME field in some zone line; the field is used as an alternate name for that zone.

Except for continuation lines, lines may appear in any order in the input.

Lines in the file that describes leap seconds have the following form:

Leap YEAR MONTH DAY HH:MM:SS CORR R/S
For example:
Leap 1974 Dec 31 23:59:60 + S
The , , , and fields tell when the leap second happened. The field should be “+” if a second was added or “-” if a second was skipped. The field should be (an abbreviation of) “Stationary” if the leap second time given by the other fields should be interpreted as UTC or (an abbreviation of) “Rolling” if the leap second time given by the other fields should be interpreted as local wall clock time.

Here is an extended example of zic input, intended to illustrate many of its features.


# Rule	NAME	FROM	TO	TYPE	IN	ON	AT	SAVE	LETTER/S
Rule	Swiss	1940	only	-	Nov	2	0:00	1:00	S
Rule	Swiss	1940	only	-	Dec	31	0:00	0	-
Rule	Swiss	1941	1942	-	May	Sun>=1	2:00	1:00	S
Rule	Swiss	1941	1942	-	Oct	Sun>=1	0:00	0

Rule	EU	1977	1980	-	Apr	Sun>=1	1:00u	1:00	S
Rule	EU	1977	only	-	Sep	lastSun	1:00u	0	-
Rule	EU	1978	only	-	Oct	 1	1:00u	0	-
Rule	EU	1979	1995	-	Sep	lastSun	1:00u	0	-
Rule	EU	1981	max	-	Mar	lastSun	1:00u	1:00	S
Rule	EU	1996	max	-	Oct	lastSun	1:00u	0	-

# Zone	NAME	GMTOFF	RULES	FORMAT	UNTIL
Zone	Europe/Zurich	0:34:08	-	LMT	1848 Sep 12
		0:29:44	-	BMT	1894 Jun
		1:00	Swiss	CE%sT	1981
		1:00	EU	CE%sT

Link	Europe/Zurich	Switzerland

In this example, the zone is named Europe/Zurich but it has an alias as Switzerland. Zurich was 34 minutes and 8 seconds west of GMT until 1848-09-12 at 00:00, when the offset changed to 29 minutes and 44 seconds. After 1894-06-01 at 00:00 Swiss daylight saving rules (defined with lines beginning with "Rule Swiss") apply, and the GMT offset became one hour. From 1981 to the present, EU daylight saving rules have applied, and the UTC offset has remained at one hour.

In 1940, daylight saving time applied from November 2 at 00:00 to December 31 at 00:00. In 1941 and 1942, daylight saving time applied from the first Sunday in May at 02:00 to the first Sunday in October at 00:00. The pre-1981 EU daylight-saving rules have no effect here, but are included for completeness. Since 1981, daylight saving has begun on the last Sunday in March at 01:00 UTC. Until 1995 it ended the last Sunday in September at 01:00 UTC, but this changed to the last Sunday in October starting in 1996.

For purposes of display, "LMT" and "BMT" were initially used, respectively. Since Swiss rules and later EU rules were applied, the display name for the timezone has been CET for standard time and CEST for daylight saving time.

For areas with more than two types of local time, you may need to use local standard time in the AT field of the earliest transition time's rule to ensure that the earliest transition time recorded in the compiled file is correct.

If, for a particular zone, a clock advance caused by the start of daylight saving coincides with and is equal to a clock retreat caused by a change in UTC offset, zic produces a single transition to daylight saving at the new UTC offset (without any change in wall clock time). To get separate transitions use multiple zone continuation lines specifying transition instants using universal time.

/usr/share/zoneinfo
standard directory used for created files

ctime(3), tzfile(5), zdump(8)

June 20, 2004 FreeBSD-12.0