NAME
comcontrol
—
control a special tty device
SYNOPSIS
comcontrol |
special_device [dtrwait number] [drainwait number] |
DESCRIPTION
Thecomcontrol
utility is used to examine and modify
some of the special characteristics of the specified tty device. If no
arguments other than the device (or "-" for stdin) are specified, it
prints the settings of all controllable characteristics. This usage requires
only read access on the device. Only the superuser can change the settings.
The following options are available:
dtrwait
number- Set the time to wait after dropping DTR to the given number. The units are hundredths of a second. The default is 300 hundredths, i.e., 3 seconds. This option needed mainly to set proper recover time after modem reset.
drainwait
number- Set the time to wait for output drain to the given number. The units are seconds. The default is 0 minutes, 0 means waiting forever. This option needed mainly to specify upper limit of minutes to prevent modem hanging.
The standard way to use comcontrol
is to
put invocations of it in the /etc/rc.d/serial
startup script.
FILES
- /dev/ttyd?
- dialin devices, hardwired terminals
- /dev/cuaa?
- dialout devices
SEE ALSO
HISTORY
Originally part of cgd's com package patches, version 0.2.1, to 386BSD-0.1. Once controlled bidirectional capabilities. Little is left to control now that these capabilities are standard.
AUTHORS
Christopher G. Demetriou